Parameter Identification For Inter Turn Fault Detection In Permanent-Magnet Synchronous Motors Using Stator Flux Linkage DC Offset Monitoring
The parameters of PMSM with inter-turn fault are identified using a time-stepping finite element method (FEM). Analytical expressions (AE) uses the estimated parameters for fault analysis similar to FEM analysis. The fault waveforms, terminal voltages, obtained from the AE models are used for inter turn fault (ITF) detection, using Stator Flux Linkage DC offset (SFDO). A comparison is made between