Status of insertion device measurement systems at MAX IV Laboratory
An insertion device lab was setup at MAX IV Laboratory and the production of insertion devices, mainly outof-vacuum is ongoing and aided by new magnetic measurement systems. A new 5.5 m long Hall probe bench is used for field map measurements and a new hybrid flip coil and stretch wire system will be used for field integrals of full devices as well as individual magnet blocks characterisation. Thi