Fluorescence microscopy for quality control in nanoimprint lithography
Fluorescence microscopy is introduced as a low cost quality control process for nanoimprint lithography. To depict imprinted structures down to 1 mum lateral size and to detect residues down to 100 nm lateral size, the standard printable polymer mr-18000 is labelled with less than 0.1 wt.% fluorescent dye. Three different types of stamps are used to determine the dependence of the shape and size o