Immune response to collagen impregnated Dacron double velour grafts for aortic and aorto-femoral reconstructions
This study presents 20 patients, randomised to receive either a collagen-treated or an ordinary Dacron graft for aortic reconstructions, and the results of a skin-prick test, blood parameters and ELISA for anti-collagen antibodies as well as NMR pictures during a 6 week follow-up period. Forty per cent (4/11) of those receiving a collagen impregnated graft had a significantly increased titre of an