Treatment of C-stage and E- stage effluents from a bleach plant using a ceramic membrane
C-stage effluent, E-stage effluent and a total effluent (C-stage and E-stage effluent mixed in proportion to the volumes of the effluents at the mill) have been treated with a ceramic microfilter membrane. The flux of the total effluent was considerably lower than of the separate effluents. The fluxes of the E-stage and C-stage effluents were 550 and 1,300 l/m2h, respectively, while the flux of th