Inverse vs. forward breast IMRT planning
Breast intensity-modulated radiation therapy (IMRT) improves dose distribution homogeneity within the whole breast. Previous publications report the use of inverse or forward dose optimization algorithms. Because the inverse technique is not widely available in commercial treatment planning systems, it is important to compare the 2 algorithms. The goal of this work is to compare them on a prospect